Difference between revisions of "Dry Etching Recipes"
(Text replacement - "www.nanotech.ucsb.edu/wiki/" to "wiki.nanotech.ucsb.edu/wiki/") |
(add a recipe) (Tag: Visual edit) |
||
Line 7: | Line 7: | ||
! colspan="3" |'''[[RIE Etching Recipes|RIE Etching]]''' |
! colspan="3" |'''[[RIE Etching Recipes|RIE Etching]]''' |
||
! colspan="5" |'''[[ICP Etching Recipes|ICP Etching]]''' |
! colspan="5" |'''[[ICP Etching Recipes|ICP Etching]]''' |
||
− | ! colspan="5" |
+ | ! colspan="5" bgcolor="#d0e7ff" align="center" |'''[[Oxygen Plasma System Recipes|Oxygen Plasma Systems]]''' |
− | ! colspan="3" |
+ | ! colspan="3" bgcolor="#d0e7ff" align="center" |'''[[Other Dry Etching Recipes|Other Dry Etchers]]''' |
|- |
|- |
||
− | ! width="65" |
+ | ! width="65" bgcolor="#d0e7ff" align="center" |'''Material''' |
| width="65" bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> (MRC)]] |
| width="65" bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> (MRC)]] |
||
| width="65" bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_3_.28MRC.29|RIE 3<br> (MRC)]] |
| width="65" bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_3_.28MRC.29|RIE 3<br> (MRC)]] |
||
Line 28: | Line 28: | ||
| width="85" bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#CAIBE_.28Oxford_Ion_Mill.29|CAIBE<br>(Oxford)]] |
| width="85" bgcolor="#daf1ff" |[[Other_Dry_Etching_Recipes#CAIBE_.28Oxford_Ion_Mill.29|CAIBE<br>(Oxford)]] |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Ag |
| |
| |
||
| |
| |
||
Line 46: | Line 46: | ||
|A |
|A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Al |
| |
| |
||
| |
| |
||
Line 64: | Line 64: | ||
|A |
|A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Au |
| |
| |
||
| |
| |
||
Line 82: | Line 82: | ||
|[https://wiki.nanotech.ucsb.edu/wiki/index.php/Other_Dry_Etching_Recipes#CAIBE_.28Oxford_Ion_Mill.29 R] |
|[https://wiki.nanotech.ucsb.edu/wiki/index.php/Other_Dry_Etching_Recipes#CAIBE_.28Oxford_Ion_Mill.29 R] |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Cr |
| |
| |
||
| |
| |
||
Line 100: | Line 100: | ||
|A |
|A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Cu |
| |
| |
||
| |
| |
||
Line 118: | Line 118: | ||
|A |
|A |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Ge |
| |
| |
||
| |
| |
||
Line 136: | Line 136: | ||
|A |
|A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Mo |
| |
| |
||
| |
| |
||
Line 154: | Line 154: | ||
|A |
|A |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Ni |
| |
| |
||
| |
| |
||
Line 172: | Line 172: | ||
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}} |
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}} |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Pt |
| |
| |
||
| |
| |
||
Line 190: | Line 190: | ||
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}} |
|{{rl|Other Dry Etching Recipes|Other Dry Etch (CAIBE (Oxford Ion Mill))}} |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Ru |
| |
| |
||
| |
| |
||
Line 208: | Line 208: | ||
|A |
|A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Si |
| |
| |
||
| |
| |
||
Line 226: | Line 226: | ||
|A |
|A |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Ta |
| |
| |
||
| |
| |
||
Line 244: | Line 244: | ||
|A |
|A |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Ti |
| |
| |
||
| |
| |
||
Line 262: | Line 262: | ||
|A |
|A |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3</sub> |
| |
| |
||
| |
| |
||
Line 280: | Line 280: | ||
|A |
|A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Al<sub>2</sub>O<sub>3 (Sapphire)</sub> |
| |
| |
||
| |
| |
||
Line 298: | Line 298: | ||
|A |
|A |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |AlGaAs |
| |
| |
||
| |
| |
||
Line 316: | Line 316: | ||
|A |
|A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |AlGaN |
| |
| |
||
| |
| |
||
Line 334: | Line 334: | ||
|A |
|A |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |AlN |
| |
| |
||
| |
| |
||
Line 352: | Line 352: | ||
|A |
|A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |CdZnTe |
|{{rl|RIE Etching Recipes|CdZnTe Etch (RIE 2)}} |
|{{rl|RIE Etching Recipes|CdZnTe Etch (RIE 2)}} |
||
| |
| |
||
Line 370: | Line 370: | ||
|A |
|A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |GaAs |
| |
| |
||
| |
| |
||
Line 388: | Line 388: | ||
|A |
|A |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |GaN |
| |
| |
||
| |
| |
||
Line 406: | Line 406: | ||
|A |
|A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |GaSb |
| |
| |
||
| |
| |
||
Line 424: | Line 424: | ||
|A |
|A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |HfO<sub>2</sub> |
| |
| |
||
| |
| |
||
Line 442: | Line 442: | ||
|A |
|A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |InGaAlAs |
|{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}} |
|{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}} |
||
| |
| |
||
Line 460: | Line 460: | ||
|A |
|A |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |InGaAsP |
|{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}} |
|{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}} |
||
| |
| |
||
Line 478: | Line 478: | ||
|A |
|A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |InP |
|{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}} |
|{{rl|RIE Etching Recipes|RIE 2 (MRC)|InP-InGaAsP-InGaAlAs Etching (RIE 2)|InP Etch (RIE 2)}} |
||
| |
| |
||
Line 494: | Line 494: | ||
| |
| |
||
| |
| |
||
− | | |
+ | |R |
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |ITO |
|{{rl|RIE Etching Recipes|ITO Etch (RIE 2)}} |
|{{rl|RIE Etching Recipes|ITO Etch (RIE 2)}} |
||
| |
| |
||
Line 533: | Line 533: | ||
|A |
|A |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |SiC |
| |
| |
||
| |
| |
||
Line 551: | Line 551: | ||
|A |
|A |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |SiN |
| |
| |
||
|{{rl|RIE Etching Recipes|RIE 3 (MRC)|SiN<sub>x</sub> Etching (RIE 3)}} |
|{{rl|RIE Etching Recipes|RIE 3 (MRC)|SiN<sub>x</sub> Etching (RIE 3)}} |
||
Line 569: | Line 569: | ||
|A |
|A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |SiO<sub>2</sub> |
| |
| |
||
|{{rl|RIE Etching Recipes|RIE 3 (MRC)|SiO<sub>2</sub> Etching (RIE 3)}} |
|{{rl|RIE Etching Recipes|RIE 3 (MRC)|SiO<sub>2</sub> Etching (RIE 3)}} |
||
Line 587: | Line 587: | ||
|A |
|A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |SiOxNy |
| |
| |
||
| |
| |
||
Line 605: | Line 605: | ||
|A |
|A |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |Ta<sub>2</sub>O<sub>5</sub> |
| |
| |
||
| |
| |
||
Line 623: | Line 623: | ||
|A |
|A |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |TiN |
| |
| |
||
| |
| |
||
Line 641: | Line 641: | ||
|A |
|A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |TiO<sub>2</sub> |
| |
| |
||
| |
| |
||
Line 659: | Line 659: | ||
|A |
|A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |W-TiW |
| |
| |
||
| |
| |
||
Line 677: | Line 677: | ||
|A |
|A |
||
|- bgcolor="#eeffff" |
|- bgcolor="#eeffff" |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |ZnO<sub>2</sub> |
| |
| |
||
| |
| |
||
Line 695: | Line 695: | ||
|A |
|A |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |ZnS |
|{{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}} |
|{{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}} |
||
| |
| |
||
Line 713: | Line 713: | ||
|A |
|A |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |ZnSe |
|{{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}} |
|{{rl|RIE Etching Recipes|ZnS Etching (RIE 2)}} |
||
| |
| |
||
Line 731: | Line 731: | ||
|A |
|A |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |ZrO<sub>2</sub> |
| |
| |
||
| |
| |
||
Line 749: | Line 749: | ||
|A |
|A |
||
|- |
|- |
||
− | ! |
+ | ! bgcolor="#d0e7ff" align="center" |'''Material''' |
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> (MRC)]] |
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_2_.28MRC.29|RIE 2<br> (MRC)]] |
||
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_3_.28MRC.29|RIE 3<br> (MRC)]] |
| bgcolor="#daf1ff" |[[RIE_Etching_Recipes#RIE_3_.28MRC.29|RIE 3<br> (MRC)]] |
Revision as of 15:43, 31 July 2020
- R = Recipe is available. Clicking this link will take you to the recipe.
- A = Material is available for use, but no recipes are provided.