+ | {| class="wikitable" border="1" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center;" |
||
+ | |- bgcolor="#D0E7FF" |
||
+ | ! width="100" |Resist |
||
+ | ! width="100" |Spin Cond. |
||
+ | ! width="75" |Bake |
||
+ | ! width="75" |Thickness |
||
+ | ! width="125" |Exposure Time |
||
+ | ! width="100" |Focus Offset |
||
+ | ! width="75" |PEB |
||
+ | ! width="100" |Developer |
||
+ | ! width="125" |Developer Time |
||
+ | ! width="300" |Comments |
||
+ | |- |
||
+ | |SPR955CM0.9 |
||
+ | |3 krpm/30” |
||
+ | |95°C/60” |
||
+ | |~ 0.9 um |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |AZ300MIF |
||
+ | | |
||
+ | | align="left" | |
||
+ | *?? |
||
+ | *{{fl|SPR955CMstepperrecipe.pdf|See SPR955CM data file}} |
||
+ | |} |
||
== Negative Resist (MLA150) == |
== Negative Resist (MLA150) == |
||
General notes: Hotplates used, filters, laser wavelengths, etc. |
General notes: Hotplates used, filters, laser wavelengths, etc. |
||
+ | |||
+ | {| class="wikitable" border="1" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center;" |
||
+ | |- bgcolor="#D0E7FF" |
||
+ | ! width="100" |Resist |
||
+ | ! width="100" |Spin Cond. |
||
+ | ! width="75" |Bake |
||
+ | ! width="75" |Thickness |
||
+ | ! width="125" |Exposure Time |
||
+ | ! width="100" |Focus Offset |
||
+ | ! width="75" |PEB |
||
+ | ! width="75" |Flood |
||
+ | ! width="100" |Developer |
||
+ | ! width="125" |Developer Time |
||
+ | ! width="300" |Comments |
||
+ | |- |
||
+ | |AZ5214 |
||
+ | |6 krpm/30” |
||
+ | |95°C/60” |
||
+ | |~ 1.0 um |
||
+ | | |
||
+ | | |
||
+ | | |
||
+ | |60" |
||
+ | |AZ300MIF |
||
+ | |60" |
||
+ | | align="left" | |
||
+ | *??? |
||
+ | |} |
Revision as of 22:24, 13 September 2020
Back to Lithography Recipes.
Work In Progress This article is still under construction. It may contain factual errors. Content is subject to change. |
Photolithography Recipes for the Heidelberg MLA150 will go here.
Positive Resist (MLA150)
General notes: Hotplates used, filters, laser wavelengths, etc.
Resist | Spin Cond. | Bake | Thickness | Exposure Time | Focus Offset | PEB | Developer | Developer Time | Comments |
---|---|---|---|---|---|---|---|---|---|
SPR955CM0.9 | 3 krpm/30” | 95°C/60” | ~ 0.9 um | AZ300MIF |
Negative Resist (MLA150)
General notes: Hotplates used, filters, laser wavelengths, etc.
Resist | Spin Cond. | Bake | Thickness | Exposure Time | Focus Offset | PEB | Flood | Developer | Developer Time | Comments |
---|---|---|---|---|---|---|---|---|---|---|
AZ5214 | 6 krpm/30” | 95°C/60” | ~ 1.0 um | 60" | AZ300MIF | 60" |
|