Difference between revisions of "Direct-Write Lithography Recipes"
Jump to navigation
Jump to search
m (John d moved page MLA150 Recipes to Maskless Aligner Recipes without leaving a redirect: higher level category) |
m |
||
Line 3: | Line 3: | ||
{{WIP}} |
{{WIP}} |
||
+ | == Heidelberg Instruments MLA150 == |
||
− | Photolithography Recipes for the [[Maskless Aligner (Heidelberg MLA150)|Heidelberg MLA150]]. |
+ | Photolithography Recipes for the [[Maskless Aligner (Heidelberg MLA150)|Heidelberg MLA150]]. ''Description of litho params- different lasers available, greyscale etc.'' |
− | == Positive Resist (MLA150) == |
+ | === Positive Resist (MLA150) === |
− | General notes: Hotplates used, filters, laser wavelengths, etc. |
+ | ''General notes: Hotplates used, filters, laser wavelengths, etc.'' |
{| class="wikitable" border="1" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center;" |
{| class="wikitable" border="1" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center;" |
||
Line 34: | Line 35: | ||
*{{fl|SPR955CMstepperrecipe.pdf|See SPR955CM data file}} |
*{{fl|SPR955CMstepperrecipe.pdf|See SPR955CM data file}} |
||
|} |
|} |
||
− | == Negative Resist (MLA150) == |
+ | === Negative Resist (MLA150) === |
− | General notes: Hotplates used, filters, laser wavelengths, etc. |
+ | ''General notes: Hotplates used, filters, laser wavelengths, etc.'' |
{| class="wikitable" border="1" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center;" |
{| class="wikitable" border="1" style="border: 1px solid #D0E7FF; background-color:#ffffff; text-align:center;" |
Revision as of 23:28, 13 September 2020
Work In Progress This article is still under construction. It may contain factual errors. Content is subject to change. |
Heidelberg Instruments MLA150
Photolithography Recipes for the Heidelberg MLA150. Description of litho params- different lasers available, greyscale etc.
Positive Resist (MLA150)
General notes: Hotplates used, filters, laser wavelengths, etc.
Resist | Spin Cond. | Bake | Thickness | Exposure Time | Focus Offset | PEB | Developer | Developer Time | Comments |
---|---|---|---|---|---|---|---|---|---|
SPR955CM0.9 | 3 krpm/30” | 95°C/60” | ~ 0.9 um | AZ300MIF |
Negative Resist (MLA150)
General notes: Hotplates used, filters, laser wavelengths, etc.
Resist | Spin Cond. | Bake | Thickness | Exposure Time | Focus Offset | PEB | Flood | Developer | Developer Time | Comments |
---|---|---|---|---|---|---|---|---|---|---|
AZ5214 | 6 krpm/30” | 95°C/60” | ~ 1.0 um | 60" | AZ300MIF | 60" |
|