Difference between revisions of "Dicing Saw (ADT)"
Jump to navigation
Jump to search
(linked to Dicing Recipes) |
(Add tape station SOP) |
||
(28 intermediate revisions by 5 users not shown) | |||
Line 2: | Line 2: | ||
|picture=ADT.jpg |
|picture=ADT.jpg |
||
|type = Packaging |
|type = Packaging |
||
− | |super= |
+ | |super= Lee Sawyer |
⚫ | |||
− | |phone= 805-893-3918x208 |
||
⚫ | |||
− | |email=hopkins@ece.ucsb.edu |
||
|description = ADT Dicing Saw |
|description = ADT Dicing Saw |
||
+ | |model = ADT 7100 |
||
|manufacturer = Advanced Dicing Technologies Ltd. |
|manufacturer = Advanced Dicing Technologies Ltd. |
||
|materials = |
|materials = |
||
|toolid=49 |
|toolid=49 |
||
}} |
}} |
||
− | == |
+ | ==About== |
− | The ADT 7100 Dicing Saw is optimized for multi-angle dicing of thin, tight tolerance products up to 200 mm x 200 mm. It is currently setup for dicing up to |
+ | The ADT 7100 Dicing Saw is optimized for multi-angle dicing of thin, tight tolerance products up to 200 mm x 200 mm. It is currently setup for dicing up to 8” diameter wafers. Check the [https://wiki.nanotech.ucsb.edu/w/index.php?title=Packaging_Recipes#Dicing_Saw_Recipes_.28ADT_7100.29 Dicing Saw Recipes page] for the blades we currently stock. |
+ | An ADT WM-966 tape applicator & Ultron Systems UH104-8 UV lamp system is used to apply UV-release tape for securing die during dicing. |
||
⚫ | |||
+ | |||
− | * Packaging Recipes > [https://www.nanotech.ucsb.edu/wiki/index.php/Packaging_Recipes?venotify=created#Dicing_Saw_Recipes_.28ADT_7100.29 Dicing Saw Recipes (ADT 7100)] |
||
+ | Contact the tool supervisor for blades and dicing frames for your group. |
||
⚫ | |||
+ | |||
+ | ==Detailed Specifications== |
||
+ | |||
+ | *Maximum Wafer Size: 8" |
||
+ | *Parts mounted to UV-release tape for cutting |
||
+ | *Automated cut maps at multiple angles (0° and 90° typical) |
||
+ | *~few micron alignment to on-wafer features. |
||
+ | *Thermocarbon Resnoid dicing blades provided by staff |
||
+ | |||
+ | ==Operating Procedures== |
||
+ | |||
+ | *[https://wiki.nanotech.ucsb.edu/w/images/1/11/ADT_SOP_Rev_E.pdf ADT Dicing Saw Standard Operating Procedure] |
||
+ | *[https://wiki.nanotech.ucsb.edu/w/images/0/01/Tape_Station_SOP_Rev_A.pdf Tape Station Standard Operating Procedure] |
||
+ | *[[ADT 7100 - Recovering an Old Recipe (2019)|Recovering an Old Recipe]] |
||
+ | |||
+ | |||
⚫ | |||
+ | |||
+ | *Recipes > Packaging > '''[[Packaging Recipes#Dicing Saw Recipes .28ADT 7100.29|Dicing Saw Recipes (ADT 7100)]]''' |
||
+ | |||
⚫ |
Revision as of 11:02, 26 April 2022
|
About
The ADT 7100 Dicing Saw is optimized for multi-angle dicing of thin, tight tolerance products up to 200 mm x 200 mm. It is currently setup for dicing up to 8” diameter wafers. Check the Dicing Saw Recipes page for the blades we currently stock.
An ADT WM-966 tape applicator & Ultron Systems UH104-8 UV lamp system is used to apply UV-release tape for securing die during dicing.
Contact the tool supervisor for blades and dicing frames for your group.
Detailed Specifications
- Maximum Wafer Size: 8"
- Parts mounted to UV-release tape for cutting
- Automated cut maps at multiple angles (0° and 90° typical)
- ~few micron alignment to on-wafer features.
- Thermocarbon Resnoid dicing blades provided by staff
Operating Procedures
- ADT Dicing Saw Standard Operating Procedure
- Tape Station Standard Operating Procedure
- Recovering an Old Recipe
Recipes
- Recipes > Packaging > Dicing Saw Recipes (ADT 7100)
Be sure to also see the recipes for protecting your sample from dicing dust, and mounting/unmounting.