Difference between revisions of "DUV Flood Expose"
Jump to navigation
Jump to search
Line 17: | Line 17: | ||
=Detailed Specifications= | =Detailed Specifications= | ||
− | *DUV wavelengths are 200-260 nm; the lamp power is limited to either | + | *DUV wavelengths are 200-260 nm; the lamp power is limited to either 1000 watts and can operate in either constant intensity or constant power mode |
*The full spectrum of Hg emission wavelengths from 200-450 nm is present on the sample | *The full spectrum of Hg emission wavelengths from 200-450 nm is present on the sample | ||
*Exposure can be performed on a 4" wafer | *Exposure can be performed on a 4" wafer |
Revision as of 11:02, 15 June 2015
<nowiki>Insert non-formatted text here<nowiki>Insert non-formatted text here</nowiki></nowiki>
|
About
This unit consists of a collimated deep ultraviolet (DUV) light source (mercury gas discharge short arc lamp) and power supply. The substrate is placed on a rotating chuck (not presently working) and is exposed by opening a timer-controlled shutter.
Materials that are exposed are primarily spun-on thin films such as PMMA, PMGI, etc.
Detailed Specifications
- DUV wavelengths are 200-260 nm; the lamp power is limited to either 1000 watts and can operate in either constant intensity or constant power mode
- The full spectrum of Hg emission wavelengths from 200-450 nm is present on the sample
- Exposure can be performed on a 4" wafer
- Lamps are nominally rated for 400 hours
- A reset timer was added in Feb. 1995 to limit "on" time (ie. provide for auto shut-off) for bulb life conservation