Difference between revisions of "Calculators + Utilities"
Jump to navigation
Jump to search
m (→Refractive Indices: specified Python) |
(→Python Scripts: added lonk to GitHub repo for Keithley I-V script) |
||
Line 33: | Line 33: | ||
* [http://www.wolframalpha.com Wolfram Alpha] |
* [http://www.wolframalpha.com Wolfram Alpha] |
||
+ | ** ''A'' ''versatile online interpreter/calculator, allowing calculations such as "''Volume of 1.5g of Silicon''", "''melting point of SiO2''" or "''520°C in Fahrenheit''".'' |
||
=== Python Scripts === |
=== Python Scripts === |
||
− | ''These scripts are best run in the Spyder IDE, which is easily installed via Anaconda, Python(X,Y), or direct compiling using a command-line package manager.'' |
+ | ''These scripts are best run in the Spyder IDE, which is easily installed via [https://www.anaconda.com/download/ Anaconda], [http://python-xy.github.io Python(X,Y)], or direct compiling using a command-line package manager.'' |
− | * [ |
+ | * [https://github.com/demisjohn/Keithley-I-V-Sweep Keithley I-V Sweep] |
− | ** Sweep voltage and plot current vs. voltage using a Keithley SMU. |
+ | ** Sweep voltage and plot current vs. voltage using a Keithley SMU. |
+ | ** Already installed at the Probe Station in Bay 4, and on the QFI Thermal Microscope (Use '''''Python(X,Y)''''' to run). |
||
+ | ** Requires the [https://pyvisa.readthedocs.io/en/stable/ pyvisa] python module. |
||
* [[QFIScope Thermal Analysis|QFIScope Thermal Analysis]] |
* [[QFIScope Thermal Analysis|QFIScope Thermal Analysis]] |
||
** Import 2D temperature data from the [[IR Thermal Microscope (QFI)]] and plot temperature profiles at specified locations. |
** Import 2D temperature data from the [[IR Thermal Microscope (QFI)]] and plot temperature profiles at specified locations. |
Revision as of 19:03, 9 November 2017
This page lists a few online calculators that are useful to lab users.
Fabrication Processes & Converters
- Thermal Oxide Calculator (BYU)
- Conversion of Pressure Units (calculatoredge.com)
- Mean Free Path tables (Pfeiffer Vacuum)
Refractive Indices
- LuxPop.com
- RefractiveIndex.info
- Filmetrics Inc.
- Ioffe Institute
- nk.py (Demis D. John)
- Python functions for returning n (ref. idx.) & k (ext. coeff.) of various NanoFab thin-films at a specified wavelength (dispersion models).
Material Parameters
- WebElements: Compounds
- Boiling points of various compounds can tell you how volatile an etch product may be in a reactive ion etch, or whether they need to be wet-etched instead.
- Physical Properties of Semiconductors (Ioffe Institute)
Wet Etching
- Transene Inc. Chemical Compatibility Chart
- A.R. Clawson, "Guide to references on III±V semiconductor chemical etching", 2001
- Enormous review of published wet etches of many semiconductors and alloys. The only thing it's missing is a hyperlinked table of contents.
General Calculators
- Anaconda Python
- A free Matlab-like IDE and GUI, using the Python language. The Spyder interface is modeled after Matlab.
- Includes the scientific Python libraries needed for array math (numpy), plotting (matplotlib), data science (pandas) and many others. Many open-source packages are available to extend capabilities.
- Octave Online Interpreter (online-utility.org)
- A Matlab-like command-line interface, powered by Python Octave.
- Wolfram Alpha
- A versatile online interpreter/calculator, allowing calculations such as "Volume of 1.5g of Silicon", "melting point of SiO2" or "520°C in Fahrenheit".
Python Scripts
These scripts are best run in the Spyder IDE, which is easily installed via Anaconda, Python(X,Y), or direct compiling using a command-line package manager.
- Keithley I-V Sweep
- Sweep voltage and plot current vs. voltage using a Keithley SMU.
- Already installed at the Probe Station in Bay 4, and on the QFI Thermal Microscope (Use Python(X,Y) to run).
- Requires the pyvisa python module.
- QFIScope Thermal Analysis
- Import 2D temperature data from the IR Thermal Microscope (QFI) and plot temperature profiles at specified locations.
- Laser Etch Monitor Simulation in Python
- Simulate your laser endpoint signal as you dry-etch through a stack of thin-film layers.