Difference between revisions of "Automated Coat/Develop System (S-Cubed Flexi)"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(Added ToolTemplate - tool type and recepe)
(Text replacement - "/wiki/index.php" to "/w/index.php")
 
(11 intermediate revisions by 3 users not shown)
Line 1: Line 1:
 
{{tool|{{PAGENAME}}
 
{{tool|{{PAGENAME}}
 
|picture=TBD.jpg
 
|picture=TBD.jpg
|type = Lithography
 
 
|super= Tony Bosch
 
|super= Tony Bosch
 
|location=Bay 7
 
|location=Bay 7
 
|description = Automatic Coat/Bake/Develop
 
|description = Automatic Coat/Bake/Develop
|manufacturer = S-Cubed
+
|manufacturer = [https://www.s-cubed.com S-Cubed]
|ToolType = Wet Processing
+
|model = Flexi (Custom)
 +
|type = Wet Processing
 
|recipe = Lithography
 
|recipe = Lithography
|materials =  
+
|materials =
|toolid=
+
|toolid=67
}}  
+
}}
 +
'''THIS TOOL IS ONLY FOR STAFF USE AT THIS TIME.'''
 +
 
 
=About=
 
=About=
  
''To Be Added''
+
The S3-Coater is a Coater/Developer system that has one photoresist spinner, one developer spinner and 4 hotplates each with independent temperature control and a chill plate. A central robot picks your wafer/s from one of 2 cassettes, processes them and returns them to the cassette. The system is recipe driven with a high degree of process control and minimal backside contamination, and coats photoresists with low particle counts/streaks and high uniformity.
 +
 
 +
At this time only full size substrates are allowed on this system. The S3 Coater is still in process development and not open for general use.
  
 
=Detailed Specifications=
 
=Detailed Specifications=
  
* Wafer Size:
+
*Wafer Size: 100mm (150mm possible but not set up)
* Photoresists/Underlayers Available:
+
*PR Coating Properties:
* Solvents Available:
+
**Uniformity < 1.0%
* Developers Available:
+
**< 100 particles on 100mm wafer
 +
*Photoresists/Underlayers Available:
 +
**UV6-0.8
 +
**DS-K101-304
 +
**PMMA
 +
**PMGI SF11
 +
**PMGI SF5
 +
*Solvents Available:
 +
**EBR100
 +
*Developers Available:
 +
**AZ 300 MiF
  
 
=Process Information=
 
=Process Information=
  
* TBD
+
*Recipe Page for S-Cubed Coater: [[Lithography Recipes#Automated%20Coat.2FDevelop%20System%20Recipes%20.28S-Cubed%20Flexi.29|Lithography Recipes > Automated Coat/Develop System Recipes (S-Cubed Flexi]])
 +
*See the [https://wiki.nanotech.ucsb.edu/w/index.php?title=Lithography_Recipes#Chemicals_Stocked_.2B_Datasheets Photolith. Chemicals page] for info on the installed resists.
  
 
=Operating Procedures=
 
=Operating Procedures=
  
* TBD
+
*[[S-Cubed Flexi - Operating Procedure|Standard Operating Procedure]] - For running pre-written recipes only.

Latest revision as of 11:50, 4 September 2021

Automated Coat/Develop System (S-Cubed Flexi)
TBD.jpg
Tool Type Wet Processing
Location Bay 7
Supervisor Tony Bosch
Supervisor Phone (805) 893-3486
Supervisor E-Mail bosch@ece.ucsb.edu
Description Automatic Coat/Bake/Develop
Manufacturer S-Cubed
Model Flexi (Custom)
Wet Processing Recipes
Sign up for this tool


THIS TOOL IS ONLY FOR STAFF USE AT THIS TIME.

About

The S3-Coater is a Coater/Developer system that has one photoresist spinner, one developer spinner and 4 hotplates each with independent temperature control and a chill plate. A central robot picks your wafer/s from one of 2 cassettes, processes them and returns them to the cassette. The system is recipe driven with a high degree of process control and minimal backside contamination, and coats photoresists with low particle counts/streaks and high uniformity.

At this time only full size substrates are allowed on this system. The S3 Coater is still in process development and not open for general use.

Detailed Specifications

  • Wafer Size: 100mm (150mm possible but not set up)
  • PR Coating Properties:
    • Uniformity < 1.0%
    • < 100 particles on 100mm wafer
  • Photoresists/Underlayers Available:
    • UV6-0.8
    • DS-K101-304
    • PMMA
    • PMGI SF11
    • PMGI SF5
  • Solvents Available:
    • EBR100
  • Developers Available:
    • AZ 300 MiF

Process Information

Operating Procedures