Difference between revisions of "Main Page"

From UCSB Nanofab Wiki
Jump to navigation Jump to search
(added announcements template in table)
('how to use...' from H5 --> H3)
Line 3: Line 3:
 
{{nav}}
 
{{nav}}
 
{| id="mp-lower" style="margin:4px 0 0 0; width:100%; background:none; border-spacing: 0px;"
 
{| id="mp-lower" style="margin:4px 0 0 0; width:100%; background:none; border-spacing: 0px;"
| class="MainPageBG" style="width:100%; border:1px solid #cedff2; background:#fff; vertical-align:top; color:#000;"|
+
| class="MainPageBG" style="width:100%; border:1px solid #cedff2; background:#fff; vertical-align:top; color:#000;" |
 
{| id="mp-upper" style="width: 100%; margin:4px 0 0 0; background:none; border-spacing: 5px;"
 
{| id="mp-upper" style="width: 100%; margin:4px 0 0 0; background:none; border-spacing: 5px;"
 
| class="MainPageBG" style="width:65%; border:1px solid #cef2e0; background:#f5fffa; vertical-align:top; color:#000;" |
 
| class="MainPageBG" style="width:65%; border:1px solid #cef2e0; background:#f5fffa; vertical-align:top; color:#000;" |
 
{| id="mp-left" style="vertical-align:top; background:#f5fffa;"
 
{| id="mp-left" style="vertical-align:top; background:#f5fffa;"
 
|-
 
|-
| style="background:#ffee55; border:1px solid #a3bfb1; color:#000;" | <div style="padding:2px 5px; text-align:left>{{Announcements}}</div>
+
| style="background:#ffee55; border:1px solid #a3bfb1; color:#000;" | <div style="padding:2px 5px; text-align:left">{{Announcements}}</div>
 
|-
 
|-
! style="padding:2px;" | <h5 id="mp-tfa-h2" style="margin:3px; background:#cef2e0; font-size:120%; font-weight:bold; border:1px solid #a3bfb1; text-align:left; color:#000; padding:0.2em 0.4em;">'''How to use this wiki'''
+
! style="padding:2px;" | <h3 id="mp-tfa-h2" style="margin:3px; background:#cef2e0; font-size:120%; font-weight:bold; border:1px solid #a3bfb1; text-align:left; color:#000; padding:0.2em 0.4em;">'''How to use this wiki'''</h3>
 
|-
 
|-
| style="color:#000;" | <div id="mp-trivia" style="padding:2px 5px"; text-align:center>{{FeaturedArticle}}
+
| style="color:#000;" | <div id="mp-trivia" style="padding:2px 5px" ; text-align:center>{{FeaturedArticle}}
 
|-
 
|-
! style="padding:2px;" | <h3 id="mp-trivia-h2" style="margin:3px; background:#cef2e0; font-size:120%; font-weight:bold; border:1px solid #a3bfb1; text-align:left; color:#000; padding:0.2em 0.4em;">'''News & Annoucements'''
+
! style="padding:2px;" | <h3 id="mp-trivia-h2" style="margin:3px; background:#cef2e0; font-size:120%; font-weight:bold; border:1px solid #a3bfb1; text-align:left; color:#000; padding:0.2em 0.4em;">'''News & Announcements'''
 
|-
 
|-
 
| style="color:#000;" | <div id="mp-trivia" style="padding:2px 5px">{{news}}
 
| style="color:#000;" | <div id="mp-trivia" style="padding:2px 5px">{{news}}

Revision as of 12:15, 28 November 2017


Welcome to the UCSB Nanofab Wiki
Arrowleft3.png See sidebar for
             Equipment & Recipes
Make sure you know the
Lab Rules
Atomic Force Microscope (Dimension ICON) - 05/08: AFM Head needs repair

I will have to take the AFM head unit back to Bruker for repair. The height sensor failed all the tests I tried so the Z-piezo/strain gauge unit will most likely need to be replaced. SO for the foreseeable future, the AFM is down.--Demis

//Vraj Mehalana 13:42, 9 May 2024 (PDT)

MA6 TSA is down - Update

After working with our FSE over the phone, we feel the culprit is a bound up Y axis motor for the top side microscope. Unfortunately, this axis is at the bottom of the microscope assembly and will require the removal of both the X and Z axis sub assemblies. I am awaiting proper instructions on how to dismantle all of this and the FSE is also checking with some of their contacts to see if there is an easier solution.


I have been asked by a few users about using the tool in TSA mode for exposures that do not require alignment even through the topside microscope is not functional. I have just tested the tool in TSA mode and it will work like this, just note that the topside microscope will not come down.

-Lee


//Vraj Mehalana 14:41, 13 May 2024 (PDT)

Velion FIB Tool DOWN

Raith service are installing and aligning a new GaBiLi source. The Velion FIB column is not available to users until further notice.

//Vraj Mehalana 10:58, 30 April 2024 (PDT)

ASML optics replacement May 20th-22nd

We will be performing beam delivery optics replacement on Mon May 20th to 22nd, to resolve a low intensity reading. The tool will be unavailable during this time.e.

//Vraj Mehalana 09:40, 9 May 2024 (PDT)

ICP1 Down

The board we were waiting on arrived, but it did not resolve the tool issue. We are working with Panasonic on the next steps. //Vraj Mehalana 14:17, 1 March 2024 (PST)

Lab Access Changes: Symmetry App

Card/Iris scanner access is still currently enabled. However we will be moving to a smartphone-based access system. IMPORTANT: check your email to setup the new smartphone access system, so you will be ready when we switch to the new system. Look for an email titled "Invitation to Access Symmetry App". // John d 13:49, 7 November 2023 (PST)

Wafer Bonder, (Suss SB6-8E)

SUSS aims to be on site in early February. We’ll will send out an email once I get confirmation for a specific date. //Vraj Mehalana 14:23, 13 December 2023 (PST)

How to use this wiki

  • NanoFab Users are responsible for understanding their chemistry, risks and usage of various chemicals. Please read the MSDS sheets for the chemicals you use!
  • Users can add qualified processing data to the Wiki pages; see the Editing_Tutorials for how to do that.
Bay3 v1.jpg
GowningRoom v2.jpg

  • Supervisors of individuals using the facility, e.g., UCSB Principal Investigators and external user managers are ultimately responsible for ensuring that their supervisees have the appropriate knowledge and training to work safely in the facility.
  • They are also responsible for ensuring that all applicable regulatory requirements are met. This includes having a compliant "Chemical Hygiene Plan" per OSHA regulations.
  • The information on this site should be considered as providing "general supporting information" to the Chemical Hygiene Plan of a particular supervisor. Supervisors can reference all or some of this site information within their Plans. UCSB EH&S can provide assistance to supervisors in preparing their Plans.


News & Announcements

News from the U.C. Santa Barbara Nanofabrication Facility.

NanoFab staff awarded Goleta's Innovator of the Year 2023

NanoFab staff member Demis D. John has been awarded the City of Goleta's "Innovator of the Year" for 2023! The award stems from the UCSB Nanofab's impact on the communities of Santa Barbara County and surrounding regions, in enabling cutting edge technology companies to thrive, which also enables many local careers in advanced high-tech. See the full announcement by the Santa Barbara South Coast Chamber of Commerce. //John d 13:58, 7 November 2023 (PST)

NanoFab Featured in Regional Tech Videos

The UCSB NanoFab is showcased as a driver of innovation and enabler of the regional high-tech industry.

See the videos here:

Santa Barbara County: This is TechTopia
Techtopia Vid - Thumbnail PlayButton.jpg
UCSB NanoFab: An Innovation Center
NanoFab COE Engineering Vid - thumbnail 2 crop.jpg

// John d 09:26, 1 November 2023 (PST)

CHIPS Act Award Announced to USC and UCSB NanoFab

U.S. Congressman Salud Carbajal congratulates UCSB and the NanoFab on receiving a CHIPS & Science Act award, as part of the California DREAMS Hub (Microelectronics Commons) led by USC. // Demis 12:06, 4 October 2023 (PDT)

JEOL SEM's Installed

Both SEM's have been replaced with new JEOL SEM's #1 and SEM #2. SEM#1 has the NABITY lithography system installed, and SEM #2 has always-on EDAX elemental analysis. Contact the supervisor, Aidan Hopkins, for more information. // John d 18:31, 20 September 2023 (PDT)

Wide FOV Microscope Installed

We have installed an AmScope stereo microscope in Bay 4 for wide field-of-view digital imaging/capture, with >2cm of FOV currently available. Wiki page here: AmScope Wide Field of View Stereoscope // John d 14:52, 19 April 2023 (PDT)

Loomis Scribe & Break installed

We have installed a new Loomis LSD-155LT Automated Scribe & Break Cleaving tool in the Back-End Processing lab. Qualifications are underway. Contact supervisor, Aidan Hopkins, for more information. // John d 09:41, 16 April 2023 (PDT)

Dektak XT installed

We have replaced the old Dektak 6M with a new Dektak XT profilometer. This tool will provide robust, fast metrology for rapid in-process topography inspection. // John d 10:41, 25 January 2023 (PST)

New Process Control data tables

We have added "Process Control Data" - data on deposition/etch repeatability - to a number of our highest used etchers and deposition tools. The datasheets are linked in multiple places, mainly on the Recipes pages for each tool, or on the general Recipes pages for Deposition Recipes or Etch Recipes. // John d 16:07, 5 January 2023 (PST)

See older articles at this link